- Product Description
-
Extremely high mechanical strength and tensile strength
Feature: The steel core provides the primary tensile strength, enabling it to withstand extremely high tensile forces.
Application: Long-Span Construction: Particularly suitable for long-distance spans, such as crossing major rivers, valleys, highways, railways, and more. Using aluminum-clad steel strands can reduce the number and height of supporting towers, thereby lowering overall costs.
High-tension requirement: Performs exceptionally well in line sections that need to withstand high tension.
Wind and ice resistance: Its high strength makes it better equipped to withstand additional loads caused by ice and strong winds, reducing the risk of wire breakage.
Good electrical conductivity
Feature: The outer aluminum layer provides an electrical conduction path. Although its conductivity is lower than that of pure aluminum, it is significantly higher than steel.
Application: Combining Conductivity and Strength—In applications requiring both excellent electrical conductivity and high tensile strength, it offers superior conductive performance compared to pure steel strands, while delivering greater strength than pure aluminum or conventional steel-core aluminum conductors.
Reducing resistive losses: When used as a ground wire, its excellent conductivity helps dissipate lightning currents and fault currents, thereby minimizing resistive losses in the line.
Excellent corrosion-resistant performance
Aluminum-layer protection: The outer aluminum-coated steel core creates an internal barrier, effectively isolating the steel core from direct contact with external corrosive agents.
Application Scenarios
Overhead Transmission Lines
Large-span conductor
High-intensity demand segment
Severely Corroded Areas
Overhead ground wire
Our Advantages
Quality Assurance
Fast Order Dispatch
Support Customization
Worry-free After-sales
Factory Live Shot
Our Advantages
T/T L/C
★ If your order is not very large, we can send it to you via TNT, DHL, UPS, or EMS.
★ If your order is large, we recommend you use air or sea freight through your designated freight forwarder. We also have long-term cooperating agents.
7 to 10 working days
7 to 10 working days
7 to 10 working days
7 to 10 working days
7-10 working days
FAQ
Delivery Method and Shipping Cost
Support FOB (Shanghai Port), CIF (Customer Designated Port), and other terms: FOB price excludes freight and insurance, CIF price includes freight and basic insurance to the destination port. Partner logistics providers include COSCO Shipping, DHL, etc., offering real-time tracking of logistics status via bill of lading number.
Delivery Time
The standard product delivery time is 15-30 days, and customized products take 3-6 weeks. Factors affecting delivery include raw material supply and production scheduling. We ensure delivery through a backup supplier database and intelligent scheduling system. In case of delay, a penalty compensation of 3% will be provided (up to a maximum of 5% of the total order amount).
Minimum order quantity
Different products have different MOQ: Power fittings 500 pieces per model, switchgear 10 units per model. Orders below MOQ will incur a 20% small order surcharge, or can be combined with other products to meet the minimum order quantity requirement.
Company R&D Capability
The R&D team accounts for 15%, with an average annual investment of 5% of sales revenue for technology upgrades. In the past 3 years, 12 utility model patents have been obtained. Customized products can be developed according to customer requirements to meet specific voltage levels and environmental adaptability (such as high temperature and high humidity).
Company Market Distribution
The product is mainly exported to Southeast Asia (Vietnam, Thailand), the Middle East (Saudi Arabia, UAE), Africa (Nigeria, Kenya), and other regions. In your area (can be identified based on customer IP), there are already 3 cooperative distributors, and anonymous customer case references can be provided (a confidentiality agreement must be signed).
Company History and Experience
Founded in 2005, with 18 years of experience in foreign trade, participated in power grid upgrade projects in multiple countries in Southeast Asia and Africa (such as the construction of a 220kV substation in Vietnam and rural power grid renovation in Kenya), serving customers in over 50 countries.
Steel Strand
Keywords:
Share Now
- Product Description
-
Extremely high mechanical strength and tensile strength
Feature: The steel core provides the primary tensile strength, enabling it to withstand extremely high tensile forces.
Application: Long-Span Construction: Particularly suitable for long-distance spans, such as crossing major rivers, valleys, highways, railways, and more. Using aluminum-clad steel strands can reduce the number and height of supporting towers, thereby lowering overall costs.
High-tension requirement: Performs exceptionally well in line sections that need to withstand high tension.
Wind and ice resistance: Its high strength makes it better equipped to withstand additional loads caused by ice and strong winds, reducing the risk of wire breakage.
Good electrical conductivity
Feature: The outer aluminum layer provides an electrical conduction path. Although its conductivity is lower than that of pure aluminum, it is significantly higher than steel.
Application: Combining Conductivity and Strength—In applications requiring both excellent electrical conductivity and high tensile strength, it offers superior conductive performance compared to pure steel strands, while delivering greater strength than pure aluminum or conventional steel-core aluminum conductors.
Reducing resistive losses: When used as a ground wire, its excellent conductivity helps dissipate lightning currents and fault currents, thereby minimizing resistive losses in the line.
Excellent corrosion-resistant performance
Aluminum-layer protection: The outer aluminum-coated steel core creates an internal barrier, effectively isolating the steel core from direct contact with external corrosive agents.
Application Scenarios
Overhead Transmission Lines
Large-span conductor
High-intensity demand segment
Severely Corroded Areas
Overhead ground wire
Fill in your phone and E-mail information, and we will contact you within one working day to promptly resolve your issues.